Caps and Plugs

Fast shipping. Consistent pricing.

Blow-off caps, vent plugs and valve caps that keep nozzles and tanks sealed until a system discharges. Choose rubber, metal or stainless steel Ansul R-102 blow-off caps, or Pyro-Chem Kitchen Knight II and Monarch caps and plugs, plus Amerex and Buckeye parts. Most blow-off caps are sold in multiples.

Categories
Categories
Product Type
Product Type
Compatibility
Compatibility
Brand
Brands
Sub Brand
Sub Brand
Ansul

Ansul R-102 Blow-Off Cap, CB Metal **Sold in Multiples of 10**

SKU: 433208

Log in for price

Ansul R-102 Blow-Off Cap, CB Metal **Sold in Multiples of 10**

SKU: 433208

The Ansul R-102 PN 433208 CB metal blow-off cap protects R-102 discharge nozzle orifices from grease and airborne contaminant buildup between service inspections. The metal construction provides durability in high-grease commercial kitchen environments. On system actuation, the cap is expelled by agent pressure, allowing unobstructed agent discharge. Inspect caps during each semi-annual NFPA 17A maintenance visit and replace any caps that are deformed, corroded, or contaminated. **Sold in Multiples of 10**.
Log in for price
Ansul

Ansul R-102 Blow-Off Cap, Metal, CB Metal, Stainless Steel **Sold in Multiples of 10**

SKU: 434707

Log in for price

Ansul R-102 Blow-Off Cap, Metal, CB Metal, Stainless Steel **Sold in Multiples of 10**

SKU: 434707

The Ansul R-102 PN 434707 CB Metal Stainless Steel blow-off cap provides superior corrosion resistance for protecting R-102 discharge nozzle orifices in demanding commercial kitchen environments. The stainless steel construction resists corrosion from acidic vapor, high humidity, and cleaning agents better than standard metal caps. On system actuation, the cap is expelled by agent pressure, allowing unobstructed agent discharge. Inspect caps during each semi-annual NFPA 17A maintenance visit and replace any caps that are deformed, corroded, or contaminated. **Sold in Multiples of 10**.
Log in for price
Ansul

Ansul R-102 Blow-Off Cap, Rubber **Sold in Multiples of 50** 77695

SKU: 77695

Log in for price

Ansul R-102 Blow-Off Cap, Rubber **Sold in Multiples of 50** 77695

SKU: 77695

The Ansul R-102 PN 77695 rubber blow-off cap is the standard nozzle cap for R-102 discharge nozzles installed in commercial kitchen exhaust systems. The flexible rubber cap seals the nozzle orifice against grease and airborne contamination between service intervals. On system actuation, the cap is ejected by agent pressure, allowing full unobstructed discharge. NFPA 17A requires inspection of blow-off caps at each semi-annual service visit and replacement of any caps that are deformed, cracked, or heavily contaminated. **Sold in Multiples of 50**.
Log in for price
Pyro-Chem

Pyro-Chem Kitchen Knight II Rubber Blow Off Cap **Sold in Multiples of 12**

SKU: 550016

Log in for price

Pyro-Chem Kitchen Knight II Rubber Blow Off Cap **Sold in Multiples of 12**

SKU: 550016

Pyro-Chem Kitchen Knight II rubber blow-off caps **Sold in Multiples of 12** protect Kitchen Knight II wet chemical nozzle orifices from grease and debris accumulation during normal kitchen operations. The rubber cap design provides a compliant, tight seal over the nozzle orifice and is engineered to blow clear upon system actuation without restricting agent discharge. Replace at every semi-annual service if deformed, torn, heavily grease-coated, or unable to seal properly. Nozzle caps are a critical inspection item — a blocked nozzle can significantly reduce suppression effectiveness. OEM Pyro-Chem Kitchen Knight II nozzle accessory.
Log in for price
Buckeye

Buckeye Valve Cap Assembly

SKU: BFR-CAP

Log in for price

Buckeye Valve Cap Assembly

SKU: BFR-CAP

The Buckeye BFR-CAP Valve Cap Assembly is required on all Kitchen Mister agent cylinders in remote-mount or multi-cylinder configurations. The cap connects the cylinder valve to the System Releasing Module via 1/4″ (0.6 cm) copper actuation tubing, allowing the releasing module to pneumatically open one or more remote cylinders on system actuation. For single-cylinder direct-mount configurations, the BFR-CAP may not be required — consult the Kitchen Mister design manual. Compatible with the BFR-TVA Test Valve Assembly for pre-installation and inspection pneumatic testing.
Log in for price
Amerex

Amerex Vent Plug

SKU: 10173

Log in for price

Amerex Vent Plug

SKU: 10173

The Amerex PN 10173 vent plug seals the discharge port of an Amerex KP agent cylinder valve assembly. Used to cap the cylinder outlet after recharge and during transport or storage, preventing agent contamination and pressure loss. Remove and replace with the distribution piping connection during system installation. For use with Amerex KP275, KP375, KP475, and KP600 cylinder assemblies.
Log in for price
Ansul

Ansul Vent Plug (R-102)

SKU: 68800

Log in for price

Ansul Vent Plug (R-102)

SKU: 68800

The Ansul R-102 PN 68800 Vent Plug Assembly is installed on the R-102 agent tank adaptor to prevent dangerous internal pressure buildup within the agent tank and agent distribution lines resulting from ambient temperature fluctuations. The vent plug provides a controlled pressure relief path that protects system integrity between service intervals. Required on tanks that are not connected to the distribution piping or that have been taken out of service. Install per the R-102 Installation and Recharge Manual. Replace the vent plug with the appropriate nozzle/piping connection at time of system commissioning.
Log in for price
Pyro-Chem

Pyro-Chem Monarch Relief Plug, High Temperature

SKU: 550026

Log in for price

Pyro-Chem Monarch Relief Plug, High Temperature

SKU: 550026

The Pyro-Chem Monarch high-temperature relief plug is used to seal and pressure-relieve openings in Monarch dry chemical system distribution piping. High-temperature formulation ensures the plug retains its seal integrity under the elevated temperatures experienced in vehicle paint spray booth environments without premature deformation or failure. Used at pipe end caps or tee plug locations in the Monarch distribution piping network. Replace if cracked, hardened, or unable to maintain a pressure-tight seal during semi-annual service. OEM Pyro-Chem Monarch system component.

Log in for price
Pyro-Chem

Pyro-Chem Kitchen Knight II Wet Valve Cap O-ring

SKU: 550714

Log in for price

Pyro-Chem Kitchen Knight II Wet Valve Cap O-ring

SKU: 550714

The Pyro-Chem Kitchen Knight II wet valve cap O-ring seals the threaded cap on the Kitchen Knight II wet valve assembly. A properly seated O-ring prevents nitrogen pressure leakage through the cap thread, ensuring the agent cylinder maintains the correct 225 psig standby pressure between service intervals. Replace the cap O-ring at every wet valve rebuild and whenever the valve cap is removed for service. Apply O-ring lubricant before reinstalling the cap. OEM Pyro-Chem replacement part; part of the Kitchen Knight II wet valve rebuilding kit (550698).

Log in for price
Pyro-Chem

Pyro-Chem Kitchen Knight II Wet Valve Cap with Valve Core

SKU: 550831

Log in for price

Pyro-Chem Kitchen Knight II Wet Valve Cap with Valve Core

SKU: 550831

The Pyro-Chem Kitchen Knight II wet valve cap with valve core is a complete replacement assembly for the cap end of the Kitchen Knight II wet valve. The valve core (Schrader-type) in the cap provides the port used to introduce nitrogen charging pressure into the agent cylinder during recharge. The complete cap-with-core assembly is replaced when the cap threads are damaged, the valve core is faulty, or after multiple service cycles where reuse may compromise seal reliability. OEM Pyro-Chem Kitchen Knight II replacement valve component.

Log in for price
Buckeye

Buckeye Metal Tethered Nozzle Cap Kit BFR-UBCT-5 (5 per Package)

SKU: BFR-UBCT-5

Log in for price

Buckeye Metal Tethered Nozzle Cap Kit BFR-UBCT-5 (5 per Package)

SKU: BFR-UBCT-5

The Buckeye metal tethered nozzle cap kit BFR-UBCT-5 contains five metal tethered blow-off caps for nozzles on the Buckeye Kitchen Mister restaurant fire suppression system. Nozzle caps keep grease and debris out of the nozzle orifice and blow off when the system discharges.

Metal caps should be removed, cleaned and checked during maintenance so they slide easily on and off the nozzle tip; replace the cap and O-ring if not. Buckeye order code BFRUBCT5.

Log in for price
Kidde

Kidde Vent Plug 1/2″ NPT for Wet Chemical Systems

SKU: 60-9196984-000

Log in for price

Kidde Vent Plug 1/2″ NPT for Wet Chemical Systems

SKU: 60-9196984-000

The Kidde vent plug PN 60-9196984-000 is installed in the discharge piping near the agent cylinder of a Kidde wet chemical kitchen system. It prevents pressure build-up in the piping, caused by heat, from rupturing the foil seals on the nozzles. It has a 1/2″ NPT male thread and must be installed in an upright or horizontal position, one per pipe network.
Log in for price

Get In Touch

Whether you're facing a challenging project or simply need advice on fire protection supplies, we're just a message away. Reach out to us via the contact form below, and our dedicated team will respond promptly.

Name(Required)
Accepted file types: jpg, jpeg, png, pdf, Max. file size: 256 MB.
SMS Text Messages