Cylinders and Tanks

Fast shipping. Consistent pricing.

Agent tanks and cylinder assemblies for kitchen suppression systems, from 1.25 gallon Kidde tanks to 6 gallon Pyro-Chem Kitchen Knight II PCL-600 cylinders. We carry Ansul R-102 and PIRANHA stainless steel tank assemblies, Amerex wet tanks and Buckeye tanks, so you can match the system already installed.

Categories
Categories
Product Type
Product Type
Compatibility
Compatibility
Brand
Brands
Sub Brand
Sub Brand
Ansul

Ansul R-102 1. 5 Gallon (UL/ULC) SS. Tank Assembly

SKU: 429864

Log in for price

Ansul R-102 1. 5 Gallon (UL/ULC) SS. Tank Assembly

SKU: 429864

The Ansul R-102 PN 429864 is a 1.5-gallon (5.68 L) stainless steel agent tank assembly for the R-102 restaurant fire suppression system. The assembly includes the stainless steel cylinder body and adaptor/tube assembly with burst disc union, which prevents agent siphoning caused by temperature variation in the field. Compatible with AnsulEX Low pH Wet Chemical Agent (sold separately). Listed under UL designation EX-3470 and ULC designation CEX-747; CE marked and Lloyd’s Register approved. Meets NFPA 96 and NFPA 17A. Operating range 32°F–130°F (0°C–54°C); hydrostatic test required every 12 years. Release mechanisms, mounting brackets, and accessories sold separately.
Log in for price
Buckeye

Buckeye 10 Flow Point Tank

SKU: BFR-10

Log in for price

Buckeye 10 Flow Point Tank

SKU: BFR-10

The Buckeye BFR-10 is a 10-flow-point pre-engineered wet chemical suppression cylinder for the Buckeye Kitchen Mister restaurant fire suppression system. Pre-charged to 195 psig (1344 kPa) at 70°F (21°C) with dry nitrogen; manufactured to DOT 4BW240. The integrated discharge valve is compatible with BFR-10R recharge agent. Part of a four-cylinder scalable family — BFR-5 through BFR-20 — allowing system design to match coverage requirements exactly. Average discharge time is under 20 seconds. Operating range: 32°F to 120°F (0°C to 49°C). Listed under UL ULEX 6885; compliant with NFPA 17A, NFPA 96, UL-300, and CE.
Log in for price
Buckeye

Buckeye 15 Flow Point Tank

SKU: BFR-15

Log in for price

Buckeye 15 Flow Point Tank

SKU: BFR-15

The Buckeye BFR-15 is a 15-flow-point pre-engineered wet chemical suppression cylinder for the Buckeye Kitchen Mister restaurant fire suppression system. Pre-charged to 195 psig (1344 kPa) at 70°F (21°C) with dry nitrogen; manufactured to DOT 4BW240. The integrated discharge valve is compatible with BFR-15R recharge agent. Part of a four-cylinder scalable family — BFR-5 through BFR-20 — allowing system design to match coverage requirements exactly. Average discharge time is under 20 seconds. Operating range: 32°F to 120°F (0°C to 49°C). Listed under UL ULEX 6885; compliant with NFPA 17A, NFPA 96, UL-300, and CE.
Log in for price
Buckeye

Buckeye 20 Flow Point Tank

SKU: BFR-20

Log in for price

Buckeye 20 Flow Point Tank

SKU: BFR-20

The Buckeye BFR-20 is a 20-flow-point pre-engineered wet chemical suppression cylinder for the Buckeye Kitchen Mister restaurant fire suppression system. Pre-charged to 195 psig (1344 kPa) at 70°F (21°C) with dry nitrogen; manufactured to DOT 4BW240. The integrated discharge valve is compatible with BFR-20R recharge agent. The largest in the four-cylinder scalable family — BFR-5 through BFR-20 — supporting the most demanding commercial kitchen system designs. Average discharge time is under 20 seconds. Operating range: 32°F to 120°F (0°C to 49°C). Listed under UL ULEX 6885; compliant with NFPA 17A, NFPA 96, UL-300, and CE.
Log in for price
Ansul

Ansul R-102 3.0 Gallon (UL/ULC) SS. Tank Assembly 429862

SKU: 429862

Log in for price

Ansul R-102 3.0 Gallon (UL/ULC) SS. Tank Assembly 429862

SKU: 429862

The Ansul R-102 3.0 Gallon (UL/ULC) SS. Tank Assembly 429862 is the agent cylinder for the R-102 restaurant fire suppression system. The stainless steel construction provides superior corrosion resistance compared to standard steel tanks, making it the preferred choice for high-humidity coastal environments and installations requiring maximum cylinder longevity. The 3.0-gallon capacity is matched to the standard R-102 pre-engineered system design. Charged with Ansulex low pH wet chemical agent and nitrogen at the factory. Pair with the appropriate AUTOMAN regulated release assembly. UL and ULC listed. OEM Ansul R-102 stainless steel tank assembly.
Log in for price
Buckeye

Buckeye 5 Flow Point Tank

SKU: BFR-5

Log in for price

Buckeye 5 Flow Point Tank

SKU: BFR-5

The Buckeye BFR-5 is a 5-flow-point pre-engineered wet chemical suppression cylinder for the Buckeye Kitchen Mister restaurant fire suppression system. Pre-charged to 195 psig (1344 kPa) at 70°F (21°C) with dry nitrogen; manufactured to DOT 4BW240. The integrated discharge valve is compatible with BFR-5R recharge agent. The smallest in the four-cylinder scalable family — BFR-5 through BFR-20 — allowing system design to match coverage requirements exactly. Average discharge time is under 20 seconds. Operating range: 32°F to 120°F (0°C to 49°C). Listed under UL ULEX 6885; compliant with NFPA 17A, NFPA 96, UL-300, and CE.
Log in for price
Ansul

Ansul Actuator, Regulated, R-102 (Order Tank Separately)

SKU: 429850

Log in for price

Ansul Actuator, Regulated, R-102 (Order Tank Separately)

SKU: 429850

The Ansul R-102 regulated actuator is the replacement actuation assembly for the AUTOMAN regulated release mechanism. The actuator initiates agent cylinder discharge when the detection wire rope is released or the manual pull station is activated. Replace the actuator after every system discharge or when internal components show wear during semi-annual inspection. Order the agent cylinder separately. OEM Ansul R-102 replacement actuator compatible with standard AUTOMAN regulated release assemblies.

Log in for price
Ansul

Ansul R-102 Air Cylinder and Tubing Assembly

SKU: 15733

Log in for price

Ansul R-102 Air Cylinder and Tubing Assembly

SKU: 15733

The Ansul R-102 air cylinder and tubing assembly provides the pneumatic actuation mechanism for R-102 restaurant fire suppression systems configured with pneumatic actuation. The compressed air or nitrogen cylinder stores actuation pressure that is released when the detection system trips, pneumatically actuating the agent cylinder valve. The assembly includes the cylinder body and interconnecting tubing. Used in system designs where pneumatic actuation is specified instead of the standard mechanical or electrical AUTOMAN. OEM Ansul R-102 pneumatic actuation component.

Log in for price
Ansul

Ansul R-102 Dual Tank Enclosure, S.S.

SKU: 429872

Log in for price

Ansul R-102 Dual Tank Enclosure, S.S.

SKU: 429872

The Ansul R-102 dual tank enclosure (stainless steel) houses and protects two R-102 wet chemical agent cylinders in systems requiring dual-cylinder capacity for larger kitchen hood coverage areas. The stainless steel enclosure provides superior corrosion resistance and a clean, finished appearance. Used with R-102 systems configured to discharge from two cylinders simultaneously for extended coverage. Compatible with all standard R-102 agent cylinders and AUTOMAN regulated release assemblies. OEM Ansul R-102 dual-cylinder housing.

Log in for price
Pyro-Chem

Pyro-Chem Monarch PAC-10 Pneumatic Actuating Cylinder

SKU: 550104

Log in for price

Pyro-Chem Monarch PAC-10 Pneumatic Actuating Cylinder

SKU: 550104

The Pyro-Chem Monarch PAC-10 pneumatic actuating cylinder provides pneumatic actuation for secondary agent cylinders or system components in Monarch dry chemical fire suppression systems. When the primary agent cylinder discharges, the pressurized gas is routed to the PAC-10, which uses that pressure to actuate additional cylinders or release mechanisms in multi-cylinder or multi-zone system designs. The PAC-10 small-volume cylinder is used where minimal actuation gas volume is required. OEM Pyro-Chem Monarch actuation component.

Log in for price
Pyro-Chem

Pyro-Chem Monarch PAC-200 Pneumatic Actuating Cylinder

SKU: 550690

Log in for price

Pyro-Chem Monarch PAC-200 Pneumatic Actuating Cylinder

SKU: 550690

The Pyro-Chem Monarch PAC-200 pneumatic actuating cylinder provides high-volume pneumatic actuation for secondary agent cylinders and system components in extended Monarch dry chemical fire suppression systems. The PAC-200’s larger volume delivers sufficient actuation pressure to trigger multiple secondary cylinders or actuate large pneumatic release mechanisms over longer actuation lines. Used in large multi-zone or multi-cylinder Monarch system configurations. OEM Pyro-Chem Monarch actuation component.

Log in for price
Pyro-Chem

Pyro-Chem Kitchen Knight II PCL-160 Agent Cylinder Assembly, 1.6 Gal.

SKU: 553163

Log in for price

Pyro-Chem Kitchen Knight II PCL-160 Agent Cylinder Assembly, 1.6 Gal.

SKU: 553163

The Pyro-Chem Kitchen Knight II PCL-160 agent cylinder assembly is a 1.6-gallon wet chemical cylinder assembly providing 5 flow points of UL 300 listed kitchen hood coverage for the Kitchen Knight II restaurant fire suppression system. The PCL-160 contains potassium carbonate wet chemical agent pressurized to 225 psig with nitrogen and includes the wet valve assembly and pressure gauge. Suitable for small single-appliance kitchen hood installations within 5-flow-point design parameters. Recharge with RL-160 agent using the PCL-AK recharge adaptor kit following system discharge. OEM Pyro-Chem Kitchen Knight II agent cylinder.

Log in for price

Get In Touch

Whether you're facing a challenging project or simply need advice on fire protection supplies, we're just a message away. Reach out to us via the contact form below, and our dedicated team will respond promptly.

Name(Required)
Accepted file types: jpg, jpeg, png, pdf, Max. file size: 256 MB.
SMS Text Messages